Metafuse Wiki© 2025 by Metafuse is licensed under CC BY-SA 4.0  

Home / DO / Materium Firmware (Klipper)

DIAGNOSE – What’s Wrong

DO – Procedures

UNDERSTAND – How It Works

DECIDE –  Is This Right For You?

MATERIUM – Extrusion System

Assembly & Installation

Materium Firmware (Klipper)

This article provides changes in your Klipper configuration (printer.cfg) necessary for Materium to work.
These changes are meant to replace the values already present in a working printer.cfg.

Only [extruder] and [bltouch] needs modification. The rest may be made because of size difference between your old extruder and Materium, if there’s any. To simulate the dimensions, find the CAD here.

The temperature sensor in Materium is PT1000, and directly connects to your printer motherboard without amplifiers. If you had intermediate boards like MAX31865 for example, skip it. If they’re built-in, you need to find a free ADC-enabled pin for the PT1000.

[extruder]
max_extrude_only_distance: 2000
max_extrude_cross_section: 200
max_extrude_only_accel: 200
step_pin: (your step_pin)
dir_pin: (your dir_pin)
enable_pin: (your enable_pin)
microsteps: 16
rotation_distance: 2.5
nozzle_diameter: 0.400
filament_diameter: 1.750
heater_pin: (your heater_pin)
sensor_type: PT1000
pullup_resistor: 4700
sensor_pin: (your sensor_pin)
control = pid
pid_Kp=21.752
pid_Ki=2.959
pid_Kd=39.969
min_temp: 0
max_temp: 350

[bltouch]
sensor_pin: (your sensor_pin)
control_pin: (your control_pin)
probe_with_touch_mode: true
stow_on_each_sample: false
speed:5
lift_speed:20
x_offset: 0
y_offset: 37

Table of Contents

Scroll to Top